HRR-SHM-CT GENERAL INFORMATION


Optima HRR-SHM-CT hydraulic road blocker test is conducted according to IWA14-1 : V/7200[N3C]/80/90:7.3 standards. HRR-SHM-CT Series crash tested road blockers are designed especially for entrance points which have a threat of vehicle attack or for the ones that have high security requirements. If there is a threat of vehicle attack in addition to the control of vehicle access in high security applications, hydraulic road blockers are the unique solution and the most secure systems. Even though the attack is from high tonnage vehicles with high speeds, it’s not possible for the vehicle to keep on moving because of the damage given to front, wheels and the bottom of the vehicle.


Optima HRR-SHM-CT shallow mount road blockers are suitable solutions which is not possible to dig the ground deeply. The road blocker depth is only 35cm.


Drive unit is hydraulic, but in case of power failure road blocker can be lowered or lifted manually with the help of manual hand pumps and valves. With the help of PLC controlled electronics, raise/lower function can be achieved by every kind of card readers, biometric readers like fingerprint or hand shape, radio control, on/off key switch etc. Besides, safety accessories like, inductive loop detectors, flashing lights or red/green lights can be integrated to the system.

STANDARD FEATURES IN HRR-SHM-CT SERIES

Test parameters

PAS68 : V/7200[N3C]/80/90:7.3

Equivalent to

K12, M50, ASTM F2656, IWA14-1

Height when raised

1250 mm

Depth

350 mm

Weight (approximately)

2000-2500 kg

Environmental durability

Red oxide painted, finishing with painted yellow & red stripes (‘STOP’ warning in the front)

Axle load

22 tons

Structure

Heavy duty

Top plate

Plain, painted to yellow with black stripes

Type of steel

S235/RAEX250-Quality 37 minimum

Red/green LED traffic light

Available, 200mm diameter, steel post 2 mt height and electrostatic ally powder coated

Hinges

Heavy duty hardened and or stainless steel AISI 303 Quality for hydraulic cylinder connections and moving part of the blocker

Bearing

Bronze

Power

380 V, 3 Phase, 50-60 Hz

Power failure

Manual hand pump

Raise lower time

3-5 seconds, in emergency 1.5 seconds (optional)

Desktop keyboard

Raise, lower, emergency stop, key operated, ‘keyboard in use’ light indicator

Extra I/O at the PLC

Enough I/O’s to connect any card reader, extra override keyboard etc. later on

Proximity switch

Available to sense the position of the blocker

Loop detector

This detector is used for safety

Power back-up system options

Hydraulic accumulator, DC motor and batteries, UPS

Cabinet

IP 65 with continuous ventilation

Motor Power

Min 4 KW, 1500 rpm

Environmental conditions

-15/+65°C, 95% humidity